Process Control and Instrumentation
141. Phase lag of the frequency response of a second order system to a sinusoidal forcing function
- Is 30°
- Is 90° at the most
- Approaches 180° asymptotically
- Is 120°
Correct answer: (C)
Approaches 180° asymptotically
142. Phase lag of the sinusoidal response of a first order system is
- 120°
- 30°
- 180°
- 90°
143. Phase margin is equal to
- 180° - phase lag
- Phase lag - 180°
- Phase lag + 180°
- Phase lag + 90°
Correct answer: (A)
180° - phase lag
144. Photoelectric pyrometers are suitable in the temperature range of _________ °C.
- 400-1600
- 800-1600
- 800-2500
- 400-1000
Correct answer: (B)
800-1600
145. Pick out the first order system from among the following.
- Damped vibrator
- Mercury in glass thermometer kept in boiling water
- Interacting system of two tanks in series
- Non-interacting system of two tanks in series
Correct answer: (B)
Mercury in glass thermometer kept in boiling water
146. Pick out the most suitable instrument for measuring temperature in the range of-40 to 425°C.
- Mercury thermometer
- Bimetallic thermometer
- Radiation pyrometer
- None of these
Correct answer: (B)
Bimetallic thermometer
147. Pick out the one which is a first order instrument.
- Mercury in glass thermometer (without any covering or air gap)
- Bare metallic thermometer
- Bare vapor pressure thermometer
- All (A), (B) and (C)
Correct answer: (D)
All (A), (B) and (C)
148. Pick out the wrong statement
- Proportional controller is normally used for level control in industrial applications
- CSTR can be considered as a distributed parameter system
- Distributed parameter approach gives partial differential equation
- Non-linear behaviour is exemplified by an on-off controller
Correct answer: (B)
CSTR can be considered as a distributed parameter system
149. Pick out the wrong statement.
- There is no transfer lag for a single first order system
- Stirred tank with a water jacket exemplifies an interacting system
- Transfer lag is a characteristic of all higher order systems (other than first order systems)
- Transfer lag decreases as the number of stages decreases
Correct answer: (D)
Transfer lag decreases as the number of stages decreases
150. Pirani gauge is used for the measurement of
- Very high pressure
- High vacuum
- Liquid level under pressure
- Liquid level at atmospheric pressure
Correct answer: (B)
High vacuum